A furnace that runs but pushes cold air out of the vents is one of the most common winter complaints. Sometimes it's a thermostat setting. Sometimes the burners aren't lighting at all and the blower is just moving room air. We connect you with a heating company in Dickerson Run, PA that can figure out which.
Check the thermostat fan setting
If the thermostat fan is set to On instead of Auto, the blower runs nonstop, including between heating cycles, so you feel cool air part of the time. Switch it to Auto and see if the problem goes away. Also make sure the system is set to Heat and not Cool or Fan.
The furnace is warming up
Many furnaces delay the blower for 30 to 90 seconds after the burners light, but some older ones start the fan early, so the first puff is cool. If the air turns warm within a minute or two, that's normal.
Real causes of cold air
- The burners aren't lighting: a failed igniter, dirty flame sensor, gas supply issue or pressure switch fault
- The burners light then shut off on the high limit because a clogged filter or failing blower is letting the heat exchanger overheat. The blower keeps running to cool it down, and that air is cool
- A condensing furnace locked out on a clogged drain or blocked vent pipe
- Leaky or disconnected ducts in an attic or crawlspace dumping heated air before it reaches the room
- Too small a gas supply or low gas pressure making a weak flame
The board's fault code usually tells the tech which. If the burners light and drop out within seconds, the flame sensor is the usual first stop.
What the tech checks
Expect a watched start-up through the sight glass, a temperature rise reading (supply air minus return air) compared to the range on the furnace's rating plate, gas pressure readings and a look at the filter, blower and limit switch. If one room is cold while others are warm, the tech may look at the duct run to that room.
What drives the cost
A thermostat setting costs nothing. A flame sensor or igniter is a modest repair. A blower motor, gas valve or duct repair in a tight attic is more. Parts on hand and labor time matter more than anything else.
Change the filter first
A dirty filter is the single most common reason a furnace overheats and blows cool air. Swap it before you call. If the problem is airflow from a failing motor, see blower motor repair. For a high-efficiency gas unit, our gas furnace repair page covers drain and vent lockouts.
Call (608) 871-1284 to get a tech in Dickerson Run, PA to find out why the air is cold.